How to Reset Ideal Logic Boiler –Step-by-Step Guide

If your boiler stops working or displays a fault code, the quickest way to restore it is to reset it. You can reset an Ideal Logic boiler (or Ideal Logic Combi 30) by pressing and holding the reset button on the control panel for a few seconds. This guide walks you through each step, explains what to check before restarting, and helps you troubleshoot if the issue comes back after resetting.

Image of steps to explain how to reset an ideal logic boiler.

How to Reset Ideal Logic Combi 30 Boiler

For the Ideal Logic Combi 30, the reset button is directly below the digital screen. It’s easy to access and clearly marked. Press it gently and hold for five seconds until you see or hear the boiler restart. Once released, allow the boiler a few minutes to run its cycle. If the pressure is correct and there are no system errors, the unit will start heating again.

When to Reset Ideal Logic Boiler

You should reset your Ideal Logic boiler if:

  • You see a fault code on the display, like fault F1 or fault F2
  • The boiler stops providing heating or hot water
  • The system shuts down after a power cut
  • You’ve just topped up the pressure
  • Avoid repeated resets. If the issue keeps coming back, the boiler needs professional inspection.

How to Restart Ideal Logic Boiler After a Fault Code

Time needed: 6 minutes

Follow the below steps to restart ideal logic boiler

  1. Check the Pressure Gauge

    Before resetting, look at the pressure gauge on the boiler’s display. If it reads below 1.0 bar, the system doesn’t have enough pressure to run safely. Many Ideal Logic fault codes, like F1 or F2, are triggered by low pressure. Resetting the boiler without topping it up won’t solve the root issue and the error may return immediately.

  2. Top Up the Pressure

    Use the filling loop located underneath the boiler to add water to the system. Slowly open both valves and watch the pressure rise. Stop when it reaches between 1.0 and 1.5 bar. This step ensures your boiler has the correct pressure to restart and run safely. Skipping this could lead to more faults or repeated lockouts.

  3. Locate the Reset Button

    Find the reset button on the boiler’s front panel, typically just below the digital display. It may be marked ‘Reset’ or ‘R’. If unsure, check the manual for your model.

  4. Press and Hold the Reset Button

    Press the reset button and hold it for 3 to 5 seconds. You may hear a click or see the display reset. This action tells the boiler to restart its operation.

  5. Wait for the Boiler to Reboot

    Allow the boiler a few minutes to complete its reset cycle. If the fault code disappears and the boiler starts running again, the reset was successful. If the error returns, you may need further troubleshooting or help from a Gas Safe engineer.

Common Reasons You May Need to Reset Ideal Boiler

You might need to reset an Ideal boiler because of:

  • Low system pressure
  • A power interruption
  • Flame detection failure (F2 code)
  • Air in the system
  • A safety lockout to prevent damage
  • Always check your manual or error code guide before resetting. If it fails more than once, contact a Gas Safe registered engineer.

Troubleshooting After Resetting Ideal Boiler

If your Ideal boiler does not restart after a reset:

  • Check the pressure again
  • Listen for strange noises from the fan or pump
  • Make sure the condensate pipe is not frozen
  • Look up the error code if it reappears
  • Do not press the reset button multiple times in a row
  • In most cases, a single reset will clear the issue. If not, the system may have a deeper fault that needs a professional diagnosis.

Conclusion

You can easily reset your Ideal Logic boiler or Ideal Logic Combi 30 by pressing and holding the reset button for a few seconds. This helps clear common faults like pressure loss or flame failure. Always make sure the pressure is correct and wait for the boiler to complete its reset cycle. If issues keep returning, get help from a Gas Safe engineer.

Frequently Asked Questions

How do you reset the Ideal Logic boiler?

Press and hold the reset button on the front panel for 3 to 5 seconds. The boiler will click, restart and begin its normal cycle.

Why is my Ideal Logic boiler not firing up?

Common reasons include low water pressure, air in the system, or a failed ignition. Check the pressure gauge and reset the boiler once the issue is fixed.

Can I reset my boiler myself?

Yes, if you follow the correct steps and safety guidelines. Modern boilers are designed to be safely reset by homeowners.

How do you restart the Ideal gas boiler?

Switch off the power, fix the underlying issue (if any), then press and hold the reset button. Wait for the system to restart fully.

Why won’t my Ideal Logic boiler turn off?

If the boiler stays on, check the thermostat, timer settings, or diverter valve. Faulty controls may need repair by an engineer.

How do you fix a flame loss on an Ideal boiler?

Check the gas supply, pressure level, and flue for blockages. If all looks fine, press the reset button to clear the F2 flame loss code.

How can I find case studies of Ideal logic boilers?

As you know Ideal heat have huge community and customers in the UK. Here is the link for you get access to Ideal case studies

Related posts

Leave a Comment


We offer over 10’000 new and refurbished heating spares. We offer 24-hour delivery.Our refurbished products are at a fraction of the price of new ones and come with a 12-month warranty for your peace of mind.We pride ourselves on providing our customers with excellent customer service from start to finish.

Payment Accepted

Contact

Build with Desol Int
0
    0
    Your Cart
    Your cart is emptyReturn to Shop